  • Section 1101.4.2 of the California Plumbing Code is amended to read:
    1101.4.2 Conductors. Conductors installed aboveground in buildings shall be in accordance with the applicable standards referenced in Table 701.2 for aboveground drain, waste, and vent pipe. Conductors installed above ground level shall be of: service weight cast-iron soil pipe or hubless cast-iron soil pipe; standard weight galvanized steel pipe; stainless steel 304 or 316L [stainless steel 304 pipe and fittings shall not be installed underground and shall be kept not less than 6 inches (152 mm) aboveground]; or Schedule 40 ABS or Schedule 40 PVC plastic pipe.
    1101.4.2.1 [HCD 1]
    ABS or PVC installations are limited to not more than two stories of areas of residential accommodation.
    1101.4.2.2 [OSHPD 1, 2, 3 & 4]
    ABS and PVC installations are not allowed.
    (Ord. 5480 § 1 (part), 2019)