§ 16.14.080. Section 301 amended - Voluntary tiers added.  


Latest version.
  • Section 301 of the California Green Building Standards Code is amended to read:
    SECTION 301
    GENERAL
    301.1 Scope. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code and any applicable local amendments. In addition, the City requires the use of Voluntary Tiers, as provided in Appendices A4 and A5, for certain residential and non-residential new construction, additions, and alterations.
    301.1.1 Residential additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions and/or alterations of existing residential buildings where the addition and/or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration.
    Tier 1 adopted (Residential). All residential building additions and/or alterations exceeding 1000 square feet must meet CALGREEN MANDATORY plus the Tier 1 requirements, as amended by this Chapter and as applicable to the scope of work.
    For Tier 1 projects, the area of alterations will include any construction or renovation to an existing structure other than repair or addition. Alterations include remodeling, reconstruction, historic restoration, changes or rearrangements of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full height partitions. Normal maintenance, reroofing, painting or wall papering, floor finishes, or replacement-in-kind of mechanical, plumbing and electrical systems are not alterations for the purposes of establishing scope of Tier 1 projects. The area of alteration should be limited to the footprint of the component(s) being altered. This does not exclude mandatory CALGreen requirements.
    Exception: Attached and detached Accessory Dwelling Units, ADU conversions of existing structures shall meet the California Green Building Standards Code Mandatory requirements only.
    301.2 Low-rise and high-rise residential buildings. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings, high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used.
    301.3 Non-residential additions and alterations. [BSC] The provisions of individual sections of Chapter 5 apply to building non-residential additions of 1,000 square feet or greater, and/or building alterations with a permit valuation of $200,000 or above (for occupancies within the authority of California Building Standards Commission). Code sections relevant to additions and alterations shall only apply to the portions of the building being added or altered within the scope of the permitted work.
    A code section will be designated by a banner to indicate where the code section only applies to newly constructed buildings [N] or to additions and alterations [A]. When the code section applies to both, no banner will be used.
    Tier 1 adopted. Non-residential alterations (including tenant improvements or renovations) of 5,000 square feet that include replacement of at least two of the following: HVAC system, building envelope, hot water system, or lighting system, must comply with CALGREEN MANDATORY plus Tier 1 requirements, as amended by this Chapter and as applicable to the scope of work.
    Tier 2 adopted. Non-residential additions of 1000 square feet or greater must comply with CALGREEN MANDATORY plus Tier 2 requirements, as amended by this Chapter and as applicable to the scope of work.
    301.1.2 Residential new construction – Tier 2 adopted. All newly constructed Residential Buildings must meet CALGREEN MANDATORY plus Tier 2 requirements, as amended by this Chapter and as applicable to the scope of work.
    Exception: Free standing detached Accessory Dwelling Units of new construction shall meet the following:
    1. California Green Building Standards Code Mandatory plus Tier 2 prerequisite requirements.
    2. No Planning and Design electives.
    3. Two (2) Water Efficiency and Conservation electives.
    4. Two (2) Material Conservation and Resource Efficiency electives.
    5. One (1) Environmental Quality elective.
    301.3.3 Non-residential new construction – Tier 2 adopted. All new non-residential construction must meet CALGREEN MANDATORY plus Tier 2 requirements, as amended by this Chapter and as applicable to the scope of work.
    301.6 Special Inspector Requirements. Residential and non-residential project owners subject to CALGREEN MANDATORY plus Tier 1 or Tier 2 requirements shall contract a Special Inspector in accordance with section 702.2 of CALGreen, as amended.
    (Ord. 5481 § 1 (part), 2019)