§ 16.17.110. Subchapter 8 - Low-rise residential buildings - performance and prescriptive compliance approaches.  


Latest version.
  • Section 150.1 - Performance and Prescriptive Compliance Approaches for Low-Rise Residential Buildings. Section 150.1 of the 2019 California Energy Code is amended to read as follows:
    (a) Section (a) is adopted without modification
    (b) Performance Standards. A building complies with the performance standards if the energy consumption for the proposed design building is no greater than the energy budget calculated for the Standard Design Building using Commission-certified compliance software as specified by the Alternative Calculation Methods Approval Manual.
    1. Newly Constructed Buildings. The Energy Budget for newly constructed buildings is expressed in terms of the Energy Design Rating, which is based on TDV energy. The Energy Design Rating (EDR) has two components, the Energy Efficiency Design Rating, and the Solar Electric Generation and Demand Flexibility Design Rating. The Solar Electric Generation and Demand Flexibility Design Rating shall be subtracted from the Energy Efficiency Design Rating to determine the Total Energy Design Rating. The Proposed Building shall separately comply with the Energy Efficiency Design Rating and the Total Energy Design Rating.
    A. An All-Electric Building complies with the performance standard if both the Total Energy Design Rating and the Energy Efficiency Design Rating for the Proposed Building are no greater than the corresponding Energy Design Ratings for the Standard Design Building.
    2. Additions and Alterations to Existing Buildings. The Energy Budget for additions and alterations is expressed in terms of TDV energy. A building complies with the performance standards if the energy consumption calculated for the Proposed Building is no greater than the energy budget calculated for the Standard Design Building.
    3. Compliance demonstration requirements for performance standards. Section 150.1(b)3A is modified to add subsection is as follows:
    i. Certificate of Compliance. The Certificate of Compliance is prepared and signed by a Certified Energy Analyst and the Total Energy Design Rating of the Proposed Design shall be no greater than the Standard Design Building.
    (Ord. 5485 § 1 (part), 2019)